







|



It is true that all these years
much of our time and effort was spent on making underground cables that are as fail proof
as can be. As a result, we have connected millions of people, playing an important role in
communications. And our efforts are still on , to bring you better products. But there are
no plans to stop with underground cables alone. and thereby ignore people who could not be
connected with underground cables due to geographic and economic reasons. In short , TRACO
has diversified into Aerial Cables.
TRACO's new range of self support
Aerial Cables connect people aerially at the same time , economically. They are
manufactured to both national and international standards .
TRACO has developed Aerially Bunched Cables for LT Overhead lines also . They are
polythene Insulated Aluminium Cables of specification : REC Specification No.s2/1984 and
have a rated voltage of 1.1 K V. This type of cables help in reducing the power
interruptions to the barest minimum level possible. Many of the advanced countries are all
ready switching over to these cables from the bare counter system.

As Al-Mg-Si Alloy is joined our
conductor family, we are growing beyond Steel. TRACO has added All Aluminium Alloy
Conductors(AAAC) to its product range and joined the energy conservation moment. Some of
the salient features which make All Aluminium Alloy Conductors (AAAC) markedly superior to
ACSR are as follows:
- High strength/weight ration: 21 to 26% lighter as
compared to ACSR . Reduction of tension is 21 to 23% and hence lighter towers would be
satisfactory- saving in cost would be greater.
- High Electrical Conductivity:- Conductivity is 6%
to 11% higher than the corresponding ACSR-Lower AC resistance and hence, considerable
decrease in line losses.
- Good corrosion Resistance:- Usage of AAAC in the
coastal area is of great significance.
- Great Abrasion and Creap Resistance:- Abration
resistance of alloy stands is more than four times that of E.C.G. Grade Aluminium. Overall
strength will not change in case of repetition short duration short circuits.
- High conductor Metal Efficiency:- Metal efficiency
of Aluminium Alloy wire is 126 whereas that of EC Grade Aluminium is only 82.
- Thermal Expansion:- Along with the rise and fall
of temperature the sag increases osr decreases to throughout the conductor.
- Connectability :- Superior to ACSR - Greater
torque can be applied without concern for the cold flow beneath the conductor.
'TRACO' CARRIES POWER ALL
OVER INDIA AND PARTICIPATES IN RAILWAY SIGNALLING
Our Bare Conductors, Weather-Proof Cables and Power are used by several Electricity Boards
in India manufactured to meet the Indian Standard Specification. With stringent quality
control methods, our cables are of excellent quality and have been acclaimed as one of the
best in the country. Our, signalling Cables made to Railway specifications are
functioning all over India. This is because TRACO NEVER COMPROMISES ON QUALITY
Self Supported Aerial Cable
Polythene Insulated Moisture barrier self supporting aerial cable. Suspension wire and
the cable core are contained in a single polythene sheath 10 pairs with 0.4, 0.5, 0.63
and 0.9 mm gauge. Spec: Telecommunication
Research Centre Spec. No. 52-23/85 TRC with reference to various ASTM, BS and IS
specification
|
PVC Drop Wire
PVC insulated drop wire Spec: ITD
Spec. No.S/WS-118D & P.V.C. insulated and polythene sheathed aerial cables 5 pairs/10
pairs
Spec. No. SP/76-2/87/63 |
Bare Conductors
Bare Conductors - AAC, ACSR and all Aluminium Alloy conductors for transmission and
distribution purposes: Spec: IS 398 Part I IS 398 Part II
IS 398 Part IV
|
Flat Twin Cable
Flat Twin weather proof cables - PVC insulated Aluminium Flat Twin Cables:
1100 V. Grade Spec: IS 694 Extensively used for providing connections to the
domestic consumer.
|
Power
Cable with Aluminium Conductor
PVC insulated and sheathed armoured/unarmoured Aluminium power cables
1100 V. Grade. Spec: IS : 1554 Part I |
Power
Cables With Copper Conductor
PVC insulated and sheathed armoured/unarmoured copper
power cables standard Specification : IS : 1554 Part I
1100 V. Grade |
Railway
Signalling Cables
Signaling Cables - Used by Railways. PVC insulated & sheathed armoured/unarmoured
Copper cables. 1100 V. Grade.
Spec : Indian Railway Specification No : S63 - 89 for PVC insulated cables
for Railway Signalling. |
|